Type AP31, AP22 and AP2022 are specially designed for Hand/Arm vibration measurements in combination with the Hand/Arm adapters AP5022, AP5023 and AP5024. The high resonance frequency of these accelerometers avoids incorrect measurements on impulsive tools. The transducer and adapterset AP5021 is developed for measurement and analysis of Hand/Arm vibrations according to ISO5349-1986 and ISO10819-1993. The sets come with three adapters for mounting a miniature accelerometer into the tool to be measured.

The tri-axial accelerometers AP81, AP2081 and AP2083 are intended for use inside the rubber seat pads for Whole Body vibration measurements. AP2081 is available with 10 mV/g and 100 mV/g sensitivity. AP2083 has a miniature multipin connector at the side allowing simple replacement of damaged cables and the use of cables with different connectors (BNC or Lemo) The tri-axial seat transducers AP5011, AP5211 and AP5213 are designed in accordance with the criteria stated in European Standard EN 1032, 1996 and intended for measurement of Whole Body Vibration according to ISO 2631 and ISO 7096.


Hand/Arm accelerometers:

AP22
Sensitivity
1 pC/g
0.1 pC/msē
Type:
Charge
Amplitude range:
25,000 g rms
Frequency range:
0,5 to 22,000 Hz
Weight:
4 g

AP2022
Sensitivity
10 mV/g
1.02 mV/msē
Type:
IEPE
Amplitude range:
450 g rms
Frequency range:
1 to 20,000 Hz
Weight:
4 g

AP31
Sensitivity
1.1 pC/g
0,1 pC/msē
Type:
Charge
Amplitude range:
20,000 g rms
Frequency range:
0.5 to 20,000 Hz
Weight:
1.3 g

 

Hand/Arm adapters:

AP5022
Frequency range:
>3.000 Hz
Weight:
16 g

AP5023
Frequency range:
>1.500 Hz
Weight:
19 g

AP5024
Frequency range:
>2.000 Hz
Weight:
30 g

 

Triaxial seat accelerometers:

AP81
Sensitivity
01 pC/g
1.02 pC/msē
Type:
Charge
Amplitude range:
2,000 g rms
Frequency range:
0,5 to 10,000 Hz
Weight:
21 g

AP2081(-100)
Sensitivity
10 / 100 mV/g
1.02 / 10.2 mV/msē
Type:
IEPE
Amplitude range:
500 / 50 g rms
Frequency range:
0,5 to 10,000 Hz
Weight:
34 g

AP2083
Sensitivity
10 mV/g
1.02 mV/msē
Type:
IEPE
Amplitude range:
500 g rms
Frequency range:
0.5 to 10,000 Hz
Weight:
34 g

 

Whole body transducers:

AP5011
Sensitivity
10 pC/g
0,1 pC/msē
Type:
Charge
Amplitude range:
2,000 g rms
Frequency range:
0.5 to >100 Hz
Weight:
395 g

AP5211(-100)
Sensitivity
10/100 mV/g
1.02 / 10.2 mV/msē
Type:
IEPE
Amplitude range:
50 g rms
Frequency range:
0.5 to >100 Hz
Weight:
408 g

AP5213
Sensitivity
10 mV/g
1.02mV/msē
Type:
IEPE
Amplitude range:
50 g rms
Frequency range:
0.5 to >100Hz
Weight:
408 g

 

 

 

 

 

 

  Copyright 1996 - , APTechnology International B.V.